4-Channel Analog Output Controller – Embedded Firmware Development
Developed the embedded firmware for an RP2040-based four-channel industrial analog output controller used as part of a wider marine / industrial electronic control system, supporting configurable current and voltage ranges (4–20 mA, 0–20 mA, 0–24 mA, 0–10 V, -10 V to +10 V). The firmware handled UART command processing, independent channel control, calibration, scaling, persistent configuration, watchdog supervision, filtering, fault handling and hardware-level validation.

The controller provided four independently controlled industrial analog output channels, supporting configurable current and voltage ranges including 4–20 mA, 0–20 mA, 0–24 mA, 0–10 V and -10 V to +10 V. The RP2040 firmware received commands over UART, processed the requested output values, applied channel-specific calibration, scaling and filtering, and controlled an external DAC / analog-output stage to generate the required industrial analog signal.
- ▸UART communication
- ▸Command parsing
- ▸Command validation
- ▸Control of four independent analog channels
- ▸Current / voltage output mode handling
- ▸Calibration
- ▸Scaling & output correction
- ▸Configuration storage
- ▸Non-volatile memory handling
- ▸Filtering
- ▸Watchdog supervision
- ▸Fault handling
- ▸Startup / initialization
- ▸Recovery behaviour
- ▸Hardware / firmware integration
- ▸Output validation
The controller was designed to operate reliably as part of a wider marine / industrial control system.
I was responsible for the embedded firmware development of the controller and its integration with the electronic hardware.
Four independent channels
Selectable per channel — ranges, not separate physical outputs
The controller was designed to support multiple analog signal ranges commonly used in industrial and marine control systems.
Industrial current-loop output with a non-zero lower bound, useful for distinguishing a valid low-scale signal from a loss-of-signal condition.
Full-range current output starting from zero current.
Extended current-output range for applications requiring additional current range or system-specific scaling.
Common unipolar industrial voltage-control range.
Bipolar voltage-output range supporting both positive and negative control signals.
Each output channel could be independently controlled and configured for the required analog range. The firmware converted the requested engineering value into the appropriate calibrated DAC command for the selected current or voltage mode.
Main flow (solid) · supporting firmware modules (dashed)
The controller received control commands over UART from a higher-level control system. Incoming commands could define the target channel, the requested output value and the selected output mode / range. The firmware parsed and validated each command, selected the channel and range, applied calibration / scaling and updated the external DAC.
Per-channel calibration was used to compensate for analog component tolerances and improve output accuracy across the supported current and voltage ranges. Calibration parameters were stored in non-volatile memory and applied by the firmware when calculating the final output command.
// Conceptual calibration model — not the exact implementation.
Calibration and operating parameters were stored in non-volatile memory so that device configuration could be restored after power cycles or resets.
The firmware was designed not only for normal operation, but also to maintain predictable behaviour when communications, configuration or runtime conditions were invalid.
- ▸Watchdog supervision
- ▸Invalid command handling
- ▸Parameter validation
- ▸Safe startup behaviour
- ▸Fault recovery logic
- ▸Predictable output behaviour during abnormal conditions
Firmware-based filtering was used to improve output stability and reduce unwanted fluctuations before updating the analog output.
Firmware and electronics were validated together, channel by channel and range by range, against measured analog outputs.
- ▸4–20 mA range verification
- ▸0–20 mA range verification
- ▸0–24 mA range verification
- ▸0–10 V range verification
- ▸-10 V to +10 V range verification
- ▸Minimum output testing
- ▸Maximum output testing
- ▸Mid-scale verification
- ▸Commanded value versus measured output
- ▸Channel-by-channel calibration verification
- ▸Output linearity checks
- ▸Configuration persistence testing
- ▸Reset / watchdog recovery testing
- ▸Invalid UART command testing
- ▸Fault-condition testing
- ▸Output behaviour during startup and recovery
// Technical details have been generalized to protect proprietary product information.